Page 561 - Hydrover-hydraulic-integrated-circuits-catalogue
P. 561
Electronic controls 61 SERIES
H6102
Technical data
Operating Voltage ........................................................................................................................................... 12 ÷ 28 VDC
Max Operating Voltage ........................................................................................................................................... 36 VDC
Nominal Power ............................................................................................................................................................ 48W
Nominal current ..............................................................................................................................2,8A (12V) - 1,4A (24V)
Supply to external potentiometer .................................................................................................................................. +5V
Minimum current swing (I min.) ..............................................................................................................................0 ÷ 50%
Maximum current swing (I max.) ....................................................................................................................I Min ÷ 100%
Ramp time swing (R. up. – R. Dw.) ................................................................................................................... 0 ÷ 10 sec.
Working temperature .......................................................................................................................................-20 ÷ +80 °C
Potentiometric input ADC resolution ...........................................................................................................................10 bit
Ordering code
H 6 1 0 2
Hydrover product Product ID
Product series
61 series - Electronic controls
September 2023 edition General catalogue 561