Page 661 - Hydrover-hydraulic-integrated-circuits-catalogue
P. 661

COMPONENTS








        Flow control, 2-way pressure compensated,

        fully adjustable

        Common cavity, Size 10
                                                                                              RE 18321-16
                                                                                              Edition: 03.2016
        VRFB-10A                                             04.02.02 - X - 85 - Z            Replaces: 09.2009



                                                              Technical data
                                                              Pressure min. - max.  14 - 350 bar (200 - 5000 psi)
                                                              Flow range            see “Regulated flow range” table
                                                              Fluid temperature range  -30 to 100 °C (-22 to 212 °F)
                                                              Installation torque   41 - 47 Nm (30 - 35 ft-lbs)
                                                              Weight 1)             0.27 kg (0.59 lbs)
                                                              Cavity                CA-10A-2N (see data sheet 18325-70)
                                                              Lines bodies and standard   Please refer to section “Hydraulic
                                                              assemblies            integrated circuit” or consult factory
                                                              Seal kit 2)           Code: RG10A2010520100
                                                                                    material no: R901111363
     Description                                              Fluids                Mineral-based or synthetics with
     A constant flow rate, regardless of system pressures, is                       lubricating properties
                                                                                                          2
     established from 1 to 2 while a minimum pressure                               at viscosities of 10 to 500 mm /s (cSt)
     differential of 14 bar (200 psi) exists between the two   Recommended degree of   Nominal value max. 10µm (NAS 8) /
                                                                                    ISO 4406 19/17/14
                                                              fluid contamination
     ports. Output flow can be varied from closed to the      Installation          No restrictions
     nominal maximum rating for the valve. Flow from 2 to 1 is   Other Technical Data  See data sheet 18350-50
     limited by the diameter of the selected control orifice and is
     not pressure compensated.                               1)  Standard version X=04 type
                                                             2)  Only external seals for 10 valves
                                                            Characteristic curve




                                                             Regulated flow








                                                                          Pressure






                                                             Turn




                                                                            Flow




                                                                        RE 18321-16/03.2016, Bosch Rexroth Oil Control S.p.A.


       Gennaio 2025 edition                            General catalogue                                        661