Page 659 - Hydrover-hydraulic-integrated-circuits-catalogue
P. 659
COMPONENTS
1/2
RE 18329-75/02.10
Replaces: RE 00162-02/01.06
Insert type
Flow control, 2-way pressure
compensated fixed setting
SFC1 0T.F1.01.00 - Y - Z
Description
A constant flow rate, regardless of system pressures, is established
from 1 to 2 while a minimum pressure differential of 145 psi exists
between the two ports. The valve cannot be adjusted for variable flow
output. Flow from 2 to 1 is limited by the diameter of the selected
control orifice and is not pressure compensated.
Technical data
Max. operating pressure bar (psi) 210 (3000)
Max. flow l/min. (gpm) see “Regulated flow range” table
Fluid temperature range °C (°F) -30 to 100 (-22 to 212)
Weight kg (lbs) see “Dimensions” table
Performance Special cavity see “Dimensions”
Mineral-based or synthetics
G 1/4 Fluids with lubricating properties at
2
viscosities of 10 to 500 mm /s (cSt)
Nominal value max. 10µm (NAS 8)
Filtration ISO 4406 19/17/14
Installation No restrictions
Other Technical Data See data sheet RE 18350-50
G 3/8 G 1/2
Gennaio 2025 edition General catalogue 659