COMPONENTS


                                                                                                         1/2
                                                                                 RE 18329-75/02.10
                                                                                 Replaces: RE 00162-02/01.06




         Insert type

         Flow control, 2-way pressure

         compensated fixed setting





         SFC1                                               0T.F1.01.00 - Y - Z


                                                     Description
                                                     A constant flow rate, regardless of system pressures, is established
                                                     from 1 to 2 while a minimum pressure differential of 145 psi exists
                                                     between the two ports.  The valve cannot be adjusted for variable flow
                                                     output.  Flow from 2 to 1 is limited by the diameter of the selected
                                                     control orifice and is not pressure compensated.




                                                     Technical data

                                                     Max. operating pressure  bar (psi) 210 (3000)
                                                     Max. flow         l/min. (gpm) see “Regulated flow range” table
                                                     Fluid temperature range  °C (°F) -30 to 100 (-22 to 212)
                                                     Weight                kg (lbs) see “Dimensions” table
         Performance                                 Special cavity                see “Dimensions”
                                                                                   Mineral-based or synthetics
                                        G 1/4        Fluids                        with lubricating properties at
                                                                                                         2
                                                                                   viscosities of 10 to 500 mm /s (cSt)
                                                                                   Nominal value max. 10µm (NAS 8)
                                                     Filtration                    ISO 4406 19/17/14
                                                     Installation                  No restrictions
                                                     Other Technical Data          See data sheet RE 18350-50









                                        G 3/8                                         G 1/2
























       Gennaio 2025 edition                            General catalogue                                        659