Page 571 - Hydrover-hydraulic-integrated-circuits-catalogue
P. 571

Multifunctional integrated circuits  97 SERIES

                                                                                                     H97009










                                               A   B
                                                                         6
                                               P   T




                                              A    B

                 A                            P    T                             B
                 1"G                                                             1"G




                                                                                        Check valve to be removed to
                              7                                       4                 exclude regenerative control.
                                                                                        Position highlighted on drawing (R).
                                                                                        1/2” G plug to screw in the B port to
                                                                                        exclude the rigenerative control.


                                                                                        Plug without P1 bypass,
                                                              4                         OD150636-Y-000000 with P1
                                                                                        bypass (MSP1).
                                                                                      T
                                                                                      1"G

                                                                8                                    ∞
              1
                                                                                      T2   5 bar
                                                                                      1"G
                                                                                      Heat exchanger
                            MP2      P2         P1      MP1                           recommended on machines
                           1/2"G   3/4"G        1/2"G   1/4"G                         that have an intense use

                            5                             5
                           Low pressure          High pressure































       September 2023 edition                          General catalogue                                        571
   566   567   568   569   570   571   572   573   574   575   576