Page 203 - Hydrover-hydraulic-integrated-circuits-catalogue
P. 203
Load sensing modular Cetop 3 subplates for parallel circuits 32 SERIES
H3219
Ordering code
H 3 2 1 9 A _ _ _ - _ _
Hydrover product Carry over *
_ = Standard
CO = T as carry over
Product series
32 series - Load sensing modular Cetop 3
subplates for parallel circuits Relief valve
adjustment pressure range *
0 = 10-60 bar
Product ID 1 = 40-110 bar
2 = 110-220 bar
3 = 220-260 bar
Manifold material
Aluminium
Relief valve
adjustment type *
Compensator spring S = Screw
5,5 bar (standard) = 6
12,5 bar = 1
19 bar = 2
Assembly example with carry over. There is a plug on the T of the flange.
Authorizes the use of the flow in excess. T becomes P1.
A B A B
M-LS
P T P T
1/4" G
H3208A-S3 H3206A H3206A H3219A6S2-CO
M
LS LS LS 1/8" G
T a
1/2" G
T T T P1
1/2" G
P P P b
P
1/2" G
A B A B
c 3/8" G 3/8" G
a. T becomes P1. The hydraulic system powered by P1 must be able to send the oil to the tank (for example a bypass).
b. The main block relief valve is active when the hydraulic system supplied by P1 send the oil to the tank.
c. This relief valve is active for the main block and P1 if the hydraulic system supplied by P1 don’t send the oil to the
tank. The pressure setting of this relief valve must be higher than the b relief valve.
September 2023 edition General catalogue 203