Page 715 - Hydrover-hydraulic-integrated-circuits-catalogue
P. 715
COMPONENTS
VEP-5A-2R-06-P
1/4
RE 18323-61/08.10
Replaces: RE 00162-02/01.06
Proportional valves pilot operated
pressure reducing
Common cavity, Size 10
VEP-5A-2R-06-P OD.91.06.77 - Y - 00
Version 06
General Electrical
Weight kg (lbs) 0.3 (0.66 ) Type of voltage 12 DC voltage
Installation orientation Optional Coil type S5
Ambient temperature range °C (°F) -30 to 60 (-22 to 140) Supply voltage See data sheet RE 18325-90
Nominal voltage ± 10%
Hydraulic Power consumption W 23
Max. operating pressure bar (psi) 250 (3600) Duty cycle % 100
Flow range l/min.(gpm) 2-60 (0.5-16) Type of protection See data sheet RE 18325-90
Max. internal cm /min. (cu.in./min.) 50 (3) Note: Coils must be ordered separately.
3
leakage
Fluid temperature range °C (°F) -20 to 80 (-4 to 176)
Mineral-based or synthetics
Fluids with lubricating properties at
viscosities of 15 to 380 mm /s (cSt)
2
Installation torque Nm (ft-lbs) 44-56 (33-41)
Nominal value max. 10µm (NAS 8)
Filtration ISO 4406 19/17/14
Cavity CA-10A-3N see RE 18325-70
Seal kit code RG10A3010520100
material no. R901111369
Seal kit coil code RG19A1PNBR7010
material no. R934003964
Other technical data See data sheet RE 18325-90
Gennaio 2025 edition General catalogue 715