Page 711 - Hydrover-hydraulic-integrated-circuits-catalogue
P. 711
Electric Drives
Linear Motion and
Service
and Controls
Hydraulics
Pneumatics
Assembly Technologies
COMPONENTS
1/4
RE 18323-65/01.10
Replaces: RE 00162-02/01.06
Proportional valves direct acting relief
Common cavity, Size 08
VEP-5B-2S-D OD.94.01.18 - Y - Z
Version 01
General Electrical
Weight kg (lbs) 0.23 (0.51) Type of voltage DC voltage
Installation orientation Optional Coil type S5
Ambient temperature range °C (°F) -30 to 60 (-22 to 140) Supply voltage 12 DC
Nominal voltage ± 10%
Hydraulic Power consumption W 23
Max. operating pressure bar (psi) 350 (5000) Duty cycle % 100
Flow range l/min.(gpm) See flow diagram Type of protection See data sheet RE 18325-90
Max. internal 3 Note: Coils must be ordered separately.
leakage (*) cm /min. (cu.in./min.) 5 (0.3)
Fluid temperature range °C (°F) -20 to 80 (-4 to 176)
Mineral-based or synthetics with
Fluids lubricating properties at viscosities
of 15 to 380 mm /s (cSt)
2
Installation torque Nm (ft-lbs) 39-51 (29-38)
Nominal value max. 10µm (NAS 8)
Filtration
ISO 4406 19/17/14
Cavity CA-08A-2N see RE 18325-70
Line bodies See data sheet RE 18325-85
code RG08A2010520100
Seal kit material no. R901101437
code RG19A1PNBR7000
Seal kit coil
material no. R934003569
Other technical data See data sheet RE 18325-90
(*) at 20% of pressure setting. Oil at 46 cSt
Gennaio 2025 edition General catalogue 711