Page 626 - Hydrover-hydraulic-integrated-circuits-catalogue
P. 626
COMPONENTS
VRPR-10A
1/2
RE 18318-53/09.09
Replaces: RE 00162-02/01.06
Pressure reducing and relieving,
direct acting spool type
Common cavity, Size 10
VRPR-10A 04.95.04 - X - 85 - Z
Description
Initially, flow passes freely from 2 to 1. When the pressure at 1
exceeds the pressure setting, the valve acts to restrict input flow at
2. This increases the pressure drop through the valve and maintains
consistent pressure at 1. The spring chamber is drained at 3 to prevent
a build-up of back-pressure against the spool. Additionally, if pressure
at 1 rises above the pressure setting, flow is relieved to 3 until the
setting is re-attained.
Technical data
Performance Max. operating pressure bar (psi) 350 (5000)
port 2 (P) 210 (3000) for version Z=01
Max. pressure admitted bar (psi) 105 (1500)
port 1 (A)
Max. flow l/min. (gpm) 30 (8)
Max. internal cm /min. (cu.in./min.) 50 (3)
3
leakage (*)
Fluid temperature range °C (°F) -30 to 100 (-22 to 212)
Installation torque Nm (ft-lbs) 41-47 (30-35)
Weight (**) kg (lbs) 0.26 (0.57)
CA-10A-3N
Cavity
see data sheet RE 18325-70
Seal kit (***) code RG10A3010520100
material no. R901111369
Mineral-based or synthetics
Fluids with lubricating properties at
viscosities of 10 to 500 mm /s (cSt)
2
Filtration Nominal value max. 10µm (NAS 8)
ISO 4406 19/17/14
Installation No restrictions
Other general technical data See data sheet RE 18350-50
(*) 1 - 3 to 80% of pressure setting
(**) Standard version X=03 type
(***) Only external seals for 10 valves
626 General catalogue September 2023 edition