Page 620 - Hydrover-hydraulic-integrated-circuits-catalogue
P. 620
COMPONENTS
1/2
RE 18318-10/05.10
Replaces: RE 00162-02/01.06
Relief, pilot operated spool type
Common cavity, Size 16
VSPN-16A 04.12.11 - X - 27 - Z
Description
Flow is blocked from 1 to 2 until pressure increases to meet the
selected valve setting, lifting the conical, pilot-stage poppet from its
seat. This action exhausts oil above the main-stage piston (spool type),
allowing it to shift and provide relief flow through 2 to tank. Pressure
at 2 is additive to the relief setting of the valve. Pilot operation is
protected from contamination by a filter screen at the bottom of the
main piston.
Performance Technical data
Max. operating pressure
port 1 (P) bar (psi) 420 (6000)
Max. pressure admitted bar (psi) 140 (2000)
port 2 (T)
Flow range l/min. (gpm) 8-300 (2-79)
Max. internal 3
leakage (*) cm /min. (cu.in./min.) 350 (21)
Fluid temperature range °C (°F) -30 to 100 (-22 to 212)
Installation torque Nm (ft-lbs) 108-122 (80-90)
Weight (**) kg (lbs) 0.45 (0.99)
CA-16A-2N
Cavity
see data sheet RE 18325-70
code RG16A2010520100
Seal kit (***) material no. R901111386
Mineral-based or synthetics
Fluids with lubricating properties at
2
viscosities of 10 to 500 mm /s (cSt)
Filtration Nominal value max. 10µm (NAS 8)
ISO 4406 19/17/14
Installation No restrictions
Other general technical data See data sheet RE 18350-50
(*) Measured at 200 bar (2900 psi)
(**) Standard version X=03 type
(***) Only external seals for 10 valves
620 General catalogue September 2023 edition