Load sensing modular Cetop 5 subplates for parallel circuits 52 SERIES

                                                                                                      H5204
                                                     Ordering code


                                         H 5       2   0    4   A _      _    _




       Hydrover product                                                                                Relief valve
                                                                                       adjustment pressure range *
                                                                               0 =                        10-70 bar
       Product series                                                          1 =                       35-140 bar
       52 series - Load sensing modular Cetop 5                                2 =                      105-210 bar
       subplates for parallel circuits                                         3 =                      175-350 bar
                                                                               3 =            35-350 bar (knob reg.)

       Product ID
                                                                                                       Relief valve
                                                                                                  adjustment type *
       Manifold material                                                    S =                              Screw
       Aluminium                                                            K =                               Knob


                                                                                               Compensator spring
                                                                       6 =                        5.5 bar (standard)
                                                                       1 =                                 12.5 bar
                                                                       2 =                                   19 bar



        * Omit if not required. To order the product without the pressure relief cartridge valve, omit the adjustment type and
        pressure range options: eg H5204A6.
        The manifold will still be provided with the corrisponding cavity.
        To inhibit the relief valve, replace the related options with TL: eg H5204A6TL.
        In the cavity it will be mounted a long plug.
        Valve                                                                     Cavity      Long plug code
        Pressure relief valve VSBN-08A                                            CA-08A-2N 0489A2005600000









































       Gennaio 2025 edition                            General catalogue                                        493