          Solenoid operated valves pilot operated poppet type

          2-way normally closed

          Special cavity, 017-E

                                                                                               RE 18323-34
                                                                                               Edition: 10.2017
          VEI-16-NC                                           OD.15 - X - 17 - Y - Z           Replaces: 09.2017


                                                              Technical data
                                                              New VEI-16 family incorporates a new solenoid concept
                                                              providing excellent performance and enables cartridges to
                                                              work in severe environment. Cartridges also incorporates
                                                              advanced design of hydraulic parts providing excellent
                                                              hydraulic performance.
                                                              Technical data
                                                               General
                                                               Weight                       0.25 kg (0.55 lbs)
                                                               Installation orientation     Unrestricted
                                                               Ambient temperature range    -30 to 90 °C (-22 to 194 °F)
                                                               Hydraulic
       PATENT PENDING                                          Max. operating pressure      350 bar (5000 psi)
                                                               Flow range                   2 - 70 l/min (0.53 - 18 gpm)
                                                               Fatigue cycle life           2 million cycles at 350 bar
                                                               Max. internal leakage:                            20 drops/min.
                                                               Installation torque          54 - 66 Nm (40 - 49 ft-lbs)
                                                               Switching time               Opening ≤ 50 ms
                                                                                            Closing ≤ 100 ms
                                                               Fluid temperature range      -20 to 80 °C (-4 to 176 °F)
                                                               Fluids: Mineral-based or synthetics with lubricating properties at
                                                               viscosities of 20 to 380 mm /s (cSt)
                                                                                   2
                                                               Recommended degree           Nominal value max. 10 µm
                                                               of fluid contamination       (NAS 8) ISO 4406 19/17/14
                                                               MTTFD                        150 years see RE 18350-51
                                                               Special cavity               017-E see 18325-75
                                                               Seal kit for X= 01,05,11  code   RG17E201052010
                                                                                  material no.  R934003562
                                                               Seal kit for X= 03,31  code   RG17E201053010
                                                                                  material no.  R934003563
                                                               Seal kit coil      code      RG01Z0010000100
                                                                                  material no.  R930058940
                                                               Other technical data         See data sheet 18350-50
                                                               Electrical
                                                               Type of voltage              DC voltage
                                                               Coil type                    D36
                                                               Supply voltage               See data sheet 18325-90
                                                               Voltage tolerance against ambient   See characteristic curve
                                                               temperature
                                                               Power consumption            20 W
                                                               Type of protection           See data sheet 18325-90