Page 473 - Hydrover-hydraulic-integrated-circuits-catalogue
P. 473

Modular Cetop 5 subplates for parallel circuits 51 SERIES

                                                                                                      H5101
                                                     Ordering code


                          H 5      1   0    1   A    -   _    _    -   _    _   -    _   _    _




       Hydrover product                                                                             Solenoid valve
                                                                                                  coil connection *
                                                                                               1 =       DIN 43650
       Product series                                                                                     ISO 4400
       51 series - Modular Cetop 5
       subplates for parallel
       circuits                                                                                     Solenoid valve
                                                                                                      coil voltage *
                                                                                         OB =              12V DC
       Product ID                                                                        OC =              24V DC
                                                                                         OD =              48V DC
                                                                                         OU =            110V RAC
       Manifold material                                                                 AH =            230V RAC
       Aluminium

                                                                                                    Solenoid valve
       Relief valve adjustment type                                                               manual override *
       Screw                                          = S                  E0 =                             Without
       Knob                                           = K                  EP =                               Push
                                                                           EG =                      Push and twist

       Relief valve adjustment pressure range
       35-140 bar                                         = 1
       70-280 bar                                         = 2
       140-420 bar                                        = 3
       35-350 bar (adj. knob)                             = 3




        * Omit if not required. To order the product without the relief cartridge valve, omit the pressure range and adjustment type
        options: eg. H5101A-E0-OC1.
        The manifold will still be provided with the corrisponding cavity.
        To inhibit the relief cartridge valve, replace the related options with TL: eg. H5101A-TL-E0-OC1.
        In the cavity it will be mounted a long plug.
        Valve                                                                  Cavity         Long plug code
        Solenoid valve OD.15.06.89-Y-000000                                    CA-12A-2N      0489A2005700000
        Pressure relief valve VSPN-10A                                         CA-10A-2N      0489A2008500000


       Note: to add stations use the intermediate / closing subplate H5102.

























       September 2023 edition                          General catalogue                                        473