Page 473 - Hydrover-hydraulic-integrated-circuits-catalogue
P. 473
Modular Cetop 5 subplates for parallel circuits 51 SERIES
H5101
Ordering code
H 5 1 0 1 A - _ _ - _ _ - _ _ _
Hydrover product Solenoid valve
coil connection *
1 = DIN 43650
Product series ISO 4400
51 series - Modular Cetop 5
subplates for parallel
circuits Solenoid valve
coil voltage *
OB = 12V DC
Product ID OC = 24V DC
OD = 48V DC
OU = 110V RAC
Manifold material AH = 230V RAC
Aluminium
Solenoid valve
Relief valve adjustment type manual override *
Screw = S E0 = Without
Knob = K EP = Push
EG = Push and twist
Relief valve adjustment pressure range
35-140 bar = 1
70-280 bar = 2
140-420 bar = 3
35-350 bar (adj. knob) = 3
* Omit if not required. To order the product without the relief cartridge valve, omit the pressure range and adjustment type
options: eg. H5101A-E0-OC1.
The manifold will still be provided with the corrisponding cavity.
To inhibit the relief cartridge valve, replace the related options with TL: eg. H5101A-TL-E0-OC1.
In the cavity it will be mounted a long plug.
Valve Cavity Long plug code
Solenoid valve OD.15.06.89-Y-000000 CA-12A-2N 0489A2005700000
Pressure relief valve VSPN-10A CA-10A-2N 0489A2008500000
Note: to add stations use the intermediate / closing subplate H5102.
September 2023 edition General catalogue 473