TECHNICAL DATA

       VALVES INSTALLATION                                                                                                                                            Hydrover product H
       It is reccomended to follow these steps:
          •  inspect the sub-plate to ensure that it is in good conditions and no external contaminant is present                                                                 Manifolds 1
          •  check that O-Rings are intact and correctly positioned
          •  don’t tighten screws or connectors more than the maximum torque specified in the catalogue                                                                 Valves for hydraulic motors 4  14 Series
                                                                                                                                                                             Multi ports manifolds 6  16 Series
       INLET VOLTAGE
       To obtain correct operation and long life of coils it is necessary that the operating voltage fluctuations do not exceed +5%                                                  Inline valves 7  17 Series
       -10 % of nominal voltage.

       TEMPERATURE RANGES                                                                                                                                             Hydrover product H
          •  Ambient Temperature from –20°C to +50°C
          •  Oil Temperature from –20°C to +80°C                                                                                                                           Cetop 3 products 3

       SEALS                                                                                                                                           Modular Cetop 3 subplates for parallel circuits 1  31 Series
       O-RINGS:  Acryl – Nitrile Butadiene Rubber NBR (BUNA-N) standard for  temperature between –20°C and +100°C.                         Load sensing modular Cetop 3 subplates for parallel circuits 2  32 Series
       Fluorocarbo FPM (Viton) and other compounds are available on request.
                                                                                                                                                                                  Cetop 3 valves 5    35 Series
       STOCKING OF NEW VALVES
       Encapsulated by a protective wrapping, the valves shall not be exposed to direct sun light nor to source of heat or ozone                                               Cetop 3 subplates 6    36 Series
       (like electric motors running) and kept in a dry place at a temperature between –20°C and +50°C.                                                                    Cetop 3 modular valves 9   39 Series

       WORKING DUTY
       The working duty ED of a coil is the ratio between energized time ti and full cycle time tc where tc=ti+tr and tr = de-energized
       time.                                                                                                                                                          Hydrover product H
                 .
       ED = (t  / t )   100 %                                                                                                                Products for Bosch Rexroth ED bankable valves  4
             i
               c
       All coils are rated for ED = 100 % provided that temperature limit of their insulation class is not exceeded.
                                                                                                                                                       Plates for Bosch Rexroth ED bankable valves 1  41 Series
       PROTECTION EN 60529
       On request coils with IP65/IP69K protection.                                                                                        Load sensing plates for Bosch Rexroth ED bankable valves 2  42 Series
                                                                                                                                         Flangeable elements for Bosch Rexroth EDC bankable valves 8  48 Series
       HYDRAULIC FLUID
       It must have physical lubricating and chemical properties suitable for use in hydraulic systems such as, for example:              Flangeable elements for Bosch Rexroth ED bankable valves 9  49 Series
          •  MINERAL OIL FLUIDS HL (DIN 51524 part1)
          •  MINERAL OIL FLUIDS HLP (DIN 51524 part2)
       For use of environmentally acceptable fluids (vegetable or polyglycol base) please consult LC Oleodinamica.                                                    Hydrover product H
       Viscosity class: with ISO-DIN, the viscosity class is expressed by ISO-VG (no.); the no. Indicates the average kinematic
       viscosity at 40°C in mm2/s or centiStoks (cSt).                                                                                                                     Cetop 5 products 5
                                                                                                                                                       Modular Cetop 5 subplates for parallel circuits 1  51 Series
       CONTAMINATION – FILTRATION
          •  GENERAL INFORMATION: Manufacturers and users of hydraulic equipment admit that contamination is the most                      Load sensing modular Cetop 5 subplates for parallel circuits 2  52 Series
           likely cause of malfunction or failure in hydraulic systems and reduces security and reliability of components and
           systems. Metal particles flowing throughout the circuit scratch moving surfaces so that contamination level, if not                                                 Cetop 5 subplates 6    56 Series
           controlled, increases very rapidly. It is strongly recomended to mantain contamination level at least at nominal values                                         Cetop 5 modular valves 9
           shown below, choosing adequate filtration products.                                                                                                                                        59 Series
          •  FILTRATION RATIO BETAx: It’s the ratio between the number of particles before and after the filter with diameter
           larger than X micron.
          •  ABSOLUTE FILTRATION RATIO ISO 4572: It’s the diameter X of the largest particle with BETAx≥ 75.                                                          Hydrover product H
          •  CONTAMINATION CLASS ISO 4406: it’s expressed by 3 scale numbers representing respectively: the number of                                                          Accessories 6
           particles equal to or larger than 4 micron (c); the number of particles equal to or larger than 6 micron (c); the number
           of particles equal to or larger than 14 micron(c), contained in 1 ml of fluid.                                                                                      Electronic controls 1  61 Series
          •  CONTAMINATION CLASS NAS 1638: It’s expressed by one scale numbers representing the number of particles of